Balston laboratory gas generators and laboratory equipment
Parker Balston gas generators for laboratory are specifically designed to meet the stringent gas requirements of producers for all the leading analytical Instrument. The equipment has been characterized by absence of pressure drops, safe and silent operation, it is user-friendly and requires minimum attention of operator.
You may have a look at description of the following types of gas generators in joint catalogue of Balston products:
- hydrogen generator with proton exchange membrane for combustion detectors, gas chromatography (Gas Chromatography PEM), hydrogen purity up to 99.9995%, flow rate from 100 to 510 ml/min, pressure up to 6.9 barG, page 7-8,
- hydrogen generator, gas chromatography palladium, mass spectrometry, carrier gas GC-PEM, hydrogen purity up to 99.99999+%, flow rate from 150 to 300 ml/min, pressure up to 4.1 barG, page 9-10,
- gas generator for flame-ionization detector; (FID), gas chromatography, hydrogen purity up to 99.9995%, flow rate from 90 to 250 ml/min, air of ultrahigh purity - rate 2500 ml/min with totl hydrocarbon content (THC) <0.05ppm, page 13-14,
- zero air generators for combustion detectors, gas chromatography, flow rate up to 30 000 ml/min, compressed air undergoes a pre-filtration up to 0.01 micron, thereafter it is using a state-of-art combined heated catalyst module, page 15-16,
- explosion proof zero air generators for FID, gas chromatography, flow rate 650 ml/min, purity <0.1 ppm for hydrocarbon, page 17-18,
- ultrahigh purity zero nitrogen generators for carrier gas and make up applications, gas chromatography, nitrogen purity 99.9995%, flow rate from 1100 to 3200 ml/min, with hydrocarbon content <0.1 ppm, pressure up to 5 barG, optionally – in-built compressor, page 19-20,
- ultrahigh purity nitrogen generators, for gas chromatography and other analytical applications, nitrogen purity 99.9995%, flow rate from 600 to 3200 ml/min, with hydrocarbon content <0.1 ppm, optionally – in-built compressor, page 21-22,
- nitrogen generator for FID make up gas, gas chromatography, zero nitrogen purity 99.9999% for THC and 99+% for О2, flow rate from 400 to 2500 ml/min, page 23-24,
- HydroGen Mate deionized water system for hydrogen generator, up to 1 l/min of deionized water, page 25-26,
- nitrogen generator, liquid chromatography and mass spectrometry, liquid chromatography with tandem mass-spectrometry (LC/MS/MS) and other applications, nitrogen purity 99.5%, phthalate and hydrocarbon-free, flow rate up to 32 l/min, pressure up to 8 barG, in-built compressor, page 29-30,
- nitrogen generator, liquid chromatography and mass spectrometry, liquid chromatography with tandem mass-spectrometry (LC/MS/MS) and other applications, nitrogen purity 99.5%, phthalate and hydrocarbon-free, flow rate from 34 to 233 l/min, pres-sure up to 10 barG, page 31-32,
- TriGas generators for applied Biosystems, liquid chromatography with tandem mass-spectrometry (LC/MS/MS), nitrogen purity 99.9%, flow rate up to 10l/min, with hydrocarbon content <0.1 ppm, zero air rate 23 l/min, dry air flow rate up to 8 l/min, dew point -40С, optionally – in-built compressor, page 33-34,
- nitrogen generator, liquid chromatography and mass spectrometry, nitrogen purity 99,%, phthalate and hydrocarbon-free, flow rate up to 500 l/min, page 35-36,
- nitrogen generator for evaporative light scattering detector (ELSD), nitrogen purity 99%, flow rate 8 l/min, page 37-38,
- purge gas generators, for Fourier transform-infrared spectroscopy (FT-IR), carbon dioxide concentration < 1.0 ppm, flow rate from 14 to 85 l/min, dew point -73С, page 41-44,
- high purity nitrogen generators for analytical instruments, including optical emission spectrometers with inductive coupled plasma, nitrogen purity up to 99.9999%, flow rate from 5.2 to 14.5 l/min, optionally – in-built compressor, page 45-46,
- dry air generators, nuclear magnetic resonance (NMR), flow rate up to 340 ml/min, dew point -73С, page 47-48,
- gas purifiers for atomic absorption spectrophotometers (АА), page 49-50,
- membrane air dryers for analytical instruments, dew point from 0 to -40С, flow rate 1203..517 l/min, page 51-52,
- - NitroVap generator, nitrogen purity up to 95%, flow rate up to 350 ml/min, an ideal generator for Turbo Vaps, sample concen-trators and solvent evaporator applications, page 53-54,
- TOC gas generators for total organic carbon analyzers, flow rate up to 1250 ml/min, dew point -73С, page 56-57.
Key application areas of Balston laboratory equipment:
- Gas chromatography (GC): flame ionization detector (FID), flame photometric detector (FPD), nitrogen phosphorous detector (NPD), electron capture detector (ECD), thermal conductivity detector (TCD), automatic thermal desorption (ATD), atomic emis-sion detector (AED), electrolytic conductivity detector (ELCD and Hall ELCD).
- Gas chromatography (GC) and mass spectrometry (MS): carrier gas.
- Liquid chromatography (LC) and mass spectrometry (MS): nebulization gas (nitrogen), source gas, exhaust gas, sheath gas, collision cell gas/drift gas, matrix assisted laser desorption ionization, Fourier transform mass spectrometry (FT/MS).
- Products for spectroscopy: Fourier transform infra-red spectrometer (FT-IR), nuclear magnetic resonance (NMR), inductively coupled plasma — mass spectrometry (ICP-MS), ICP optical spectrometers (ICP-OS), optical emission spectrometers (ICP-OES), atomic emission spectrometers (AA - flame), particle sizing instruments or sieve signal.
- Products for analyzers: total organic carbon analyzer (TOC), total hydrocarbon analyzer (THA), differential scanning calorimetry (DSC), thermal gravimetric analyzer (TGA), СО2 analyzer (CO2 Analyzer), chemisorption/ physisorption.
- Other applications: sample preparation/solvent evaporators, circular dichroism (CD), evaporative light scattering detector (ELSD), Corona charged aerosol detector (CAD), condensation nucleation light scattering detector (CNLSD), СО2 thermostats or incubators (in vitro fertilization (IVF), Stem Cell & Regenerative Medicine), chemical vapour deposition instrumentation (CVD), plasma cleaning instrumentation (UCP), digital radiography (Edge, General Electric, Varian Medical), hydrogenation (organic chemistry).
Selection of gas generators and other Parker Domnick Hunter laboratory equipment is possible in section Domnick Hunter laboratory gas generators,